LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2006 >> CL500 >> Repair and Diagnosis >> Body & Frame >> Ignition Switch/Steering Lock >> Anti-Theft & Central Locking - 215 & 220 Chassis >> Basic Knowledge >> Automatic locking, function - GF80.20-P-4009S

Automatic locking, function - GF80.20-P-4009S

MODEL 215, 220 

Function prerequisite 

The vehicle is unlocked with the remote control key  (or on model 220, USA ONLYJAPAN ONLY with the lock switches  ).

Function sequence 

The "automatic locking" function locks the vehicle centrally except the tank flap as soon as the vehicle speed exceeds the limit value  of approx. 15 km/h.

This is accomplished as soon as the PSE control module (combined) (A37)  recognizes that the threshold value is exceeded by evaluating the speed signals on the CAN bus. The PSE control module (combined) (A37)  locks the doors pneumatically.

The trunk lid  is locked.

The vehicle can be unlocked by opening a door  from the inside or with the interior central locking switch (N72/1s6)  if the vehicle speed is below the limit.

If the vehicle is unlocked with the interior central locking switch (N72/1s6)  following automatic locking  the vehicle remains unlocked even at speeds exceeding the limit speed  . The system returns to the initial status when a door is opened  or circuit 15 is switched on  or off  .

If a door is opened following automatic locking  and is closed again while the vehicle speed is above the limit speed the  door in question  is locked again after it is closed.

IMPORTANT The automatic locking function can be deactivated or activated:

  Unlocking with remote control key, function   GF80.20-P-3006S 
  Actuation of lock switches, function Model 220 only USA ONLYJAPAN ONLY GF80.20-P-3007S 
  Unlocking by opening one door, function   GF80.20-P-3004S 
  Locking/unlocking pneumatically, function   GF80.20-P-4016S 
  Instrument cluster (IC), function   GF54.30-P-0002S
  Pneumatic system equipment (PSE), combined functions, location/purpose/design/function   GF80.20-P-4106S