Throttle valve actuator, ME-SFI fault code description - AD07.61-P-4000-49L
| Throttle valve actuator | ||
| 1 | Fault code ( |
P2032 Throttle valve, actual value potentiometer (P0120) |
| 2 | Fault storage | After expiry of test duration and fault |
| Activation of the engine diagnosis indicator lamp (EURO3/4) or CHECK ENGINE (MIL) malfunction indicator lamp |
Following two successive driving cycles with faults | |
| 3 | Checking frequency | Continuous |
| 4 | Checked signal or status | Signals from actual value potentiometers 1 and 2 |
| 5 | Fault setting conditions | |
| Voltage difference between signal 1 and signal 2 |
|
|
| Short circuit to positive | If signal 1 is larger than 4.85 V or signal 2 larger than 4.75 V, a short-circuit to positive is present (12 V or 5 V) or the throttle valve actuator is faulty. | |
| Open circuit | If signal 1 is smaller than 0.275 V or signal 2 smaller than 0.175 V, an interruption is present or the throttle valve actuator is faulty.. | |
| 6 | Check prerequisites |
|
| 7 |
|
|
| Both actual value potentiometers work in opposite directions. |