LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2006 >> C280 Base >> Repair and Diagnosis >> Engine Performance >> Tune-Up >> Mixture Formation -- Self-Diagnostic System -- 203 Chassis - 2 Of 2 >> Self-Diagnostic System >> Purge control valve vacuum control - ME-SFI gasoline injection system - Testing electrical system - AD07.61-P-6000-30A

Purge control valve vacuum control - ME-SFI gasoline injection system - Testing electrical system - AD07.61-P-6000-30A

HAND-HELD TESTER Scope of test Tester/test connection Operation/Prerequisite: Specified value
  • Possible cause/Remedy
1.0  Purge control valve (Y58/1)    Connect vacuum tester at Y58/1 between the purge line to the activated charcoal container.  
  • Vacuum lines
  • Y58/1
P0440          
P0441 Vacuum control        
P0446          
      Engine at operating temperature and at idle speed.    
        After approx. 2 min.
> 5 mbar and pointer swings; in this case, Y58/1 must actuate cyclically.