Ventilation, function - GF83.10-P-2000N
MODEL 215
Ventilation, function
Function
The ventilation
- keeps the windows from fogging up.
- Supply of fresh air for vehicle passengers.
- helps to quickly achieve and maintain a uniform and pleasant temperature in the passenger compartment.
Ventilation of the passenger compartment is supported by the blower for the air conditioning (automatic) during normal operation, when the vehicle is standing still or when an increased air flow rate is required.
Fresh air is sucked in through the air inlet in the engine hood and through the fresh air flap in the AC housing. The air flows through the air ducts to the air outlets in the passenger compartment depending on the pushbutton control module setting. In the recirculated air mode air is sucked in from the passenger compartment by the blower through the recirculated air flap and transferred to the AC housing.
The air flows through the ventilation slots below the rear shelf into the trunk and exits the vehicle through the rear vents.
| Air inlet, location/function | GF83.10-P-2138I | ||
| Air ducts, location/purpose | GF83.10-P-2139N | ||
| Blower, location/purpose/design/function | GF83.10-P-2140I | ||
| Blower regulator, location/purpose/function | GF83.10-P-2141I | ||
| Dust filter, location/purpose/function | GF83.10-P-2142I | ||
| Rear ventilation, location/purpose/function | GF83.10-P-2143I | ||
| Defroster nozzle, location/purpose/function | GF83.10-P-2144I | ||
| Center nozzle, location/purpose/design/ function | GF83.10-P-2107I | ||
| Side nozzle, location/purpose/design/function | GF83.10-P-2108I | ||
| Front footwell air outlet, location/purpose/ function | GF83.10-P-2145I | ||
| Rear footwell air outlet, location/purpose/ function | GF83.10-P-2146N | ||
| Rear nozzle, location/purpose/design/function | GF83.10-P-2111I | ||
| Stowage compartment ventilation nozzle, location/purpose/function | GF83.10-P-2147I | ||
| Defroster nozzle flap actuator motor, location/ purpose/function | GF83.10-P-2129I | ||
| Diverter flap actuator motor, location/purpose/ function | GF83.10-P-2130I | ||
| Blend flap actuator motor, location/purpose/ function | GF83.10-P-2131I | ||
| Footwell flap actuator motor, location/purpose/ function | GF83.10-P-2132I | ||
| Door vent, location/purpose/function | GF83.10-P-2133I | ||
| Multifunction sensor, location/purpose/function | GF83.10-P-2148I | ||
| Fresh air/recirculated air flap, location/ purpose/design/function | GF83.20-P-2104I | ||
| Air distribution switch, location/purpose/ function | GF83.25-P-2103I | ||
| Fresh air/recirculated air flap actuator motor, location/purpose/function | GF83.30-P-2116I | ||
| Activated charcoal filter actuator motor, location/purpose/function | GF83.30-P-2117I | ||
| Activated charcoal filter, location/purpose/ function | GF83.30-P-2118I | ||
| Blower button, location/purpose/function | GF83.40-P-2144I | ||
| Recirculated air button, location/purpose/ function | GF83.40-P-2145I | ||
| Automatic air conditioning housing, location/ purpose/design/function | GF83.40-P-2105I | ||
| Auto button, location/purpose/function | GF83.40-P-2147I | ||
| Activated charcoal filter button, location/ purpose/function | GF83.40-P-2149I | ||
| Defroster button, location/purpose/function | GF83.40-P-2139I | ||
| Center nozzle electronics control module, location/purpose | GF83.40-P-2157I | ||
| Electronic stepping motor control module, location/purpose | GF83.40-P-2158I |