Self-monitoring function - GF86.10-P-2002MB

MODEL 220.175 /178 with CODE (Z04) Light armoring with CODE (Z07) Top protection with fire extinguishing system 

Each time the ignition is switched on the functional availability of the fire extinguishing system is checked by the fire extinguishing system control module (N100).

The following statuses are monitored: 

If the extinguishing system is working properly, the function illumination in the activation and triggering button in the fire extinguishing system manual triggering switch illuminates (S62/23) for 10 sec. when the ignition is switched on and then goes off.

If a fault was detected in the fire extinguishing system, the fire extinguishing system warning buzzer goes off for 10 sec. (H13) and the function illumination in the fire extinguishing system manual triggering switch activate button (S62/23) is continuously on (this alarm is repeated each time the ignition is switched on until the fault is remedied).

  Manual trigger switch location and function   GF86.10-P-2102MB 
  Warning buzzer location/task   GF86.10-P-2103MB 
  Extinguishing agent canister pressure monitoring switch location/task   GF86.10-P-2105MB 
  Fire extinguishing system control module location/task   GF86.10-P-2104MB