LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2005 >> E55 >> Repair and Diagnosis >> Brakes >> Mechanical - Hydraulic >> Overall Vehicle - Basic Knowledge - 211 Chassis - 2 Of 2 >> Basic Knowledge >> Active service system (ASSYST PLUS), function - GF00.20-P-0004 >> Active service system (ASSYST PLUS), function - GF00.20-P-0004TA >> Notes

Active service system (ASSYST PLUS), function - GF00.20-P-0004TA: Notes

MODEL 211 with ENGINE 642 

MODEL 211 with ENGINE 271 as of 1.6.05 

MODEL 211 with ENGINE 272 

General information 

Calculation of the service date is determined by the ASSYST system. Additional maintenance items are handled by the ASSYST PLUS system.

ASSYST PLUS determines, from measured values or variables determined there from as well as from data stored in its read-only memory, the next service date due for the vehicle in question. Both distance-related and time-related variables are taken into account. ASSYST PLUS can be configured, enabling it to be adapted to various vehicle uses. This is implemented in the central gateway control unit (N93).

The central gateway control unit (N93) is connected to the vehicle control units via the Controller Area Network bus, Class B (interior) (CAN B) and Controller Area Network bus, Class C (engine compartment) (CAN C).

During configuration of the maintenance algorithm, it is determined whether the required data is acquired solely by the system or whether it is taken from other modules, such as the ASSYST. ASSYST only takes into account the oil change intervals; ASSYST PLUS covers all vehicle maintenance requirements.

IMPORTANT ASSYST PLUS is implemented as a module in parallel with ASSYST.

Operation during the vehicle's first 250 km 

ASSYST PLUS is linked primarily to the Controller Area Network (data bus/CAN bus) (CAN) messages provided by the instrument cluster (A1). For the instrument cluster (A1) it is possible to reset the main odometer within the first 250 km of vehicle operation. An instrument cluster (A1) reset is no longer possible after the 250 km limit has been reached.

ASSYST PLUS does not perform any maintenance item calculations until this distance has been reached. However, upon reaching the main odometer, the traveled distance of 250 km is once taken into consideration in calculating and evaluating the maintenance items. This main odometer threshold is not taken into consideration again by ASSYST PLUS.

The following modules are integrated into the central gateway control unit (N93):

Data analysis 

Single or a number of stored service items with their intervals can be assigned to the basic items.

All service events are stored in the history memory and can be read out at any time via STAR DIAGNOSIS.

The service calculation module calculates an optimum service scope from the data from all the integrated modules using an internal computation.

This service scope takes the model designation, the date, the mileage, service-related special equipment and retrofitted installations into consideration.

If the service date has been reached, the service indicator in the instrument cluster (A1) is activated automatically via ASSYST PLUS.

Display 

The displays are shown in the multifunction display (A1p13) of the instrument cluster (A1). The following instructions can be displayed with service codes:

A "+" after the service indicator identifies the degree of wear of the brake linings. The brake lining thickness must be checked on the service date.

The service date is displayed at least 1000 km or 30 days before the next service is due. The service display consists of the term "Service" followed by the specific service code.

The service code includes the time taken and is classified from A to H:

The service interval can be displayed on driver request or upon exceeding a warning threshold automatically as the remaining distance in the multifunction display (A1p13).

Technology and influencing factors 

ASSYST PLUS needs the values of various influential parameters to calculate the requirement-based service interval.

In addition to the evaluation factors, which depend on the real-life driving conditions, quality factors may also be used to determine the monitored service interval (remaining distance and remaining time).

Various readings listed below are required for data capture.

The following data from the CAN-B is required:

The following data from the CAN-C is required:

IMPORTANT ASSYST PLUS diagnosis is performed using STAR DIAGNOSIS. Entry is accomplished via the central gateway control unit (N93), which is connected to the data link connector (X11/4).

In addition to calculating the next service date, the indication for the next main vehicle inspection date and the emissions inspection date are calculated and displayed in the multifunction display (A1p13) using ASSYST PLUS in the central gateway control unit (N93).

IMPORTANT Before the instrument cluster (A1) can be replaced, the trip odometer must be read out. Following this, the instrument cluster (A1) to be replaced can be replaced with a new one.

Before learning in, the key ID on the instrument cluster (A1) it is necessary for the trip odometer readout to be written to the new instrument cluster (A1). Only then, it is possible to perform the learning operation for the key ID.

In the event of a malfunction in the instrument cluster (A1) or in the EZS control unit (N73) service data is no longer transferred and is kept at the last current status.

IMPORTANT If service was confirmed on the instrument cluster (A1) or with STAR DIAGNOSIS even though no service was performed, this service confirmation must be reset immediately. Only the last confirmation can be reset.

  Active service system (ASSYST PLUS), operating instructions   GF00.20-P-0004-01TA 
  Active Service System (ASSYST PLUS), driver information   GF00.20-P-0004-02TA 
  Active service system (ASSYST PLUS), component networking   GF00.20-P-0004-04TA 
  Remaining distance, function   GF00.20-P-2007TA 
  Remaining time, function   GF00.20-P-2008T 
  Engine oil monitoring, function   GF00.20-P-2009TA 
  Display service scope, function Up to 31.5.05 GF00.20-P-2010T 
    As of 1.6.05 GF00.20-P-2010TA 
  Read out service memory, function   GF00.20-P-2012T