Home >> Mercedes Benz >> 2005 >> E55 >> Repair and Diagnosis >> Accessories & Equipment >> Infotainment >> Electrical System, Equipment & Instructions - Retrofitting & Conversion - 211 Chassis - 1 Of 2 >> Retrofitting & Conversion >> Retrofit ultrasonic back-up assist - AZ54.65-P-0001 >> Retrofit ultrasonic back-up assist - AZ54.65-P-0001TT >> Routing and connecting wiring harness - AZ54.65-P-0001-06TT

Routing and connecting wiring harness - AZ54.65-P-0001-06TT

  1. Prepare parking assist wiring harness (25) as shown in the diagram and route in the vehicle.
    Fig 1: Identifying Rear SAM Control Module With Fuse And Relay Module
    G04984494
  2. Connect parking assist wiring harness (25) to socket 17 (arrow) in rear SAM control module with fuse and relay module (N10/2) in left side of trunk.
  3. Connect parking assist wiring harness (25) to rear bumper PTS connector (X35/28).
    Fig 2: Identifying Parking Assist Wiring Harness
    G04984495
  4. Route parking assist wiring harness (25) along the left side wall as shown in the diagram to the overhead control and frame floor system connector (X25/8) and connect warning element wiring harness (22).
  5. Fasten wiring harnesses with cable straps.
    Fig 3: Identifying Overhead Control And Frame Floor System Connector
    G04984496
  6. Route parking assist wiring harness (25) in left-hand cable duct to the area of the left A-pillar.
  7. Unclip left voltage distributor (CAN) connector (X30/7) from cable duct and unlock.
  8. Connect branch-off line from parking assist wiring harness (25) to left voltage distributor (CAN) connector (X30/7).
  9. Lock voltage distributor and clip into cable duct.
    Fig 4: Identifying Voltage Distributor (CAN) Connector
    G04984497