Notes on application of sealant to right-hand crankcase - AH01.40-P-1000-02A
Engine 137.970
Application of sealant to right-hand crankcase cover
The line F penciled in identifies the application of sealant.
The sealant should only be applied to the areas specified with a 2.0 mm ± 0.5 mm bead.
The sealant must be used within 10 minutes. The silicone bead must not be spread. Only the approved silicone sealant should be used.