Notes on application of sealant to cylinder shutoff oil pump - AH01.30-P-1000-01A
Engine 137.970
Application of sealant to cylinder shutoff oil pump
The timing case cover is sealed with silicone sealant at the points F .
Only apply the sealant to the specified line (F) with a 2.0 mm ± 0.5 mm bead.
The sealant must be used within 10 minutes. The silicone bead must not be spread. Only the approved silicone sealant should be used.