Close function - GF68.50-P-2002PC
MODEL 203.7 with CODE (413) panoramic sliding roof
Function requirements
- No overvoltage/undervoltage
- Circuit 15R ON or
- Circuit 15 ON and
- Panoramic sliding roof closed
- The overhead control panel control module (N70) detects the neutral position (switch not activated for 40 ms)
Function
The "close sun blind" function is only available when the sun blind drive unit (M24) is in the normalized state .
It is deployed by moving the roof system switch (N70s1) toward the front of the vehicle. The roof system switch (N70s1) must remain manually pressed. The overhead control panel control module (N70) then actuates the sun blind motor (M24m1) which closes the sun blind. The motor operates for as long as the switch is activated or until the sun blind reaches its end position.
The "close sun blind" function is aborted if lock-up
of the sun blind is detected.
The sun blind drive unit (M24) is not provided with an obstruction sensor .
| Open function | GF68.50-P-2003PC | ||
| Lock-up recognition function | GF68.50-P-2005PC | ||
| Normalization function | GF68.50-P-2007PC | ||
| Panoramic sliding roof roller blind location/task/ design/function | GF68.50-P-4101PC | ||
| Overhead control panel control module location/ task/design/function | GF82.20-P-4101PP |