LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2005 >> C55 >> Repair and Diagnosis >> Accessories & Equipment >> Collision/Avoidance >> Back-Up & Parking Assist -- Retrofitting & Conversion -- 203 Chassis >> Retrofitting & Conversion >> Installing control module - AZ54.65-P-0001-04MS

Installing control module - AZ54.65-P-0001-04MS

203.2 

  1. Carefully loosen insulation from sheet metal above left wheelhouse.
  2. Use ultrasonic PTS control module (62) as template and transfer holes (see arrow in figure section) to left side wall of trunk (see arrows).

    IMPORTANT Install control module with plug locations downward.

  3. Drill holes with 5 mm dia. bit (see arrows).
    Fig 1: Identifying PTS Control Module And Transfer Holes
    G04733910
  4. Insert connector for ultrasonic back-up assist wiring harness (1) into plug location for ultrasonic PTS control module (62).

    IMPORTANT Plug locations are coded and cannot be mixed up.

    Fig 2: Identifying PTS Control Module And Wiring Harness
    G04733911
  5. Install one sheet metal clip each on the ultrasonic PTS control module (62) (see single figure).
  6. Screw ultrasonic PTS control module (62) with 4.2x22 mm sheet metal screw behind sheet metal part (see arrows).

    IMPORTANT Install control module with plug locations downward.

  7. Glue insulation back on.
    Fig 3: Locating PTS Control Module And Sheet Metal Screw
    G04733912