LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2004 >> SLK32 >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Electrical System, Equipment & Instructions -- 170 Chassis >> Testing & Repair >> Check quiescent current consumption - AR54.10-P-1030C >> Notes

Check quiescent current consumption - AR54.10-P-1030C: Notes

MODEL 170 

Modification notes

5.8.04 Prerequisites and sequence of quiescent current testing expanded Steps 2.1, 5.1, 6.1: model 170 with Audio 10 CD radio  
1.1 Prepare test with quiescent current retention unit   AR54.10-P-1030-01AD 
    SPECIAL TOOL Electrical connection set Figure
    COMMERCIALLY AVAILABLE TOOLS Multimeter *WH58.30-Z-1001-09A 
    COMMERCIALLY AVAILABLE TOOLS Quiescent current retention unit CMP 12.2 *WH58.30-Z-1012-09A 
1.2 Preparing test without quiescent current retention device   AR54.10-P-1030-02AD 
    SPECIAL TOOL Electrical connection set Figure
    COMMERCIALLY AVAILABLE TOOLS Multimeter *WH58.30-Z-1001-09A 
2.1 Preparatory measures for the quiescent current check IMPORTANT Model 170 with MB Audio 10 RDS radio with CD drawer only, code 756. AR54.10-P-1000-01GH 
3 Switch off all consumers IMPORTANT Close roof, Remove ignition key, Switch off stationary heater, Switch off car telephone, Switch off radio (except model 170 with MB
Audio 10 RDS radio with CD drawer, code 756), Switch off interior protection, Switch off make-up mirror and Switch off reading lamp, Turn exterior lamp switch to position "0", Close doors, the interior lights must go out automatically after a few seconds, close luggage compartment cover.
 
4 Check quiescent current If specification for total quiescent current is not achieved: ↓ AR54.10-P-1030-03C 
    Determine circuit with increased quiescent current consumption
Specification not achieved: ↓
AR54.10-P-1030-04C 
    Determine fuse-protected components with increased quiescent current consumption
Specification not achieved: ↓
AR54.10-P-1030-05AB 
    Determine non-fuse protected components with increased quiescent current consumption
IMPORTANT If the specified value is not attained during the quiescent current test, then the quiescent current test should be carried out again after eliminating the fault.
AR54.10-P-1030-06AB 
    SPECIAL TOOL Electrical connection set Figure
    SPECIAL TOOL Quiescent current test adapter 1 Figure
    SPECIAL TOOL Quiescent current test adapter 2 Figure
    COMMERCIALLY AVAILABLE TOOLS Multimeter *WH58.30-Z-1001-09A 
5.1 Preparatory measures for reference test of quiescent current consumption IMPORTANT Model 170 with MB Audio 10 RDS radio with CD drawer only, code 756. AR54.10-P-1000-01GH 
6.1 Carry out reference test for quiescent current consumption IMPORTANTModel 170 with MB Audio 10 RDS radio with CD drawer only, code 756  : on vehicles with an extreme suspicion of an increased quiescent current and a correct result of quiescent current consumption, a reference test of quiescent current consumption must be carried out.
IMPORTANT Whilst retaining the adjustments for reference test described in step 5.1, the quiescent current must have fallen by 600 mA after 20 minutes at the latest. If the quiescent current does not fall but remains at the same level: ↓
AR54.10-P-1030-03C 
    Replace MB Audio 10 RDS radio with CD AR82.60-P-7502EB
Fig 1: Identifying Electrical Connection Set (201 589 00 99 00)
G04743730
Fig 2: Identifying Quiescent-Current Test Adapter 1 (140 589 12 21 00)
G04743731
Fig 3: Identifying Quiescent Current Test Adapter 2 (140 589 13 21 00)
G04743732
Commercially available tools

Number Designation
WH58.30-Z-1001-09A Multimeter
WH58.30-Z-1012-09A Quiescent current retention unit