Retrofitting wiring harness - AZ82.70-P-0001-04AB
- Converting telephone wiring harness as shown in figure.
- Tie out antenna lead compensator (12) and tie out power supply wiring harness (13) to length of approx. 500 mm.
- Disconnect standard antenna lead (11) in trunk on left from rod antenna connector (A28x1).
- Route antenna lead (11) into trunk
- Connect standard antenna lead (11) and new antenna lead compensator (12) to E-net compensator (A28/3).
- Connect power supply wiring harness (13).
- Route antenna lead compensator (12) to left C-pillar and connect to rod antenna connector (A28x1).
- Open standard wiring harness at telephone interface (A34/4), expose black/violet lead (sw/vi) circuit 15, red/ violet lead (rt/vi) circuit 30 and brown lead (br) circuit 31.
- Solder violet lead (vi) from power supply wiring harness (13) to black/violet lead from standard wiring harness.
- Solder red/violet lead (rt/vi) from wiring harness (13) to red/violet lead (rt/vi) from standard wiring harness.
- Solder brown lead (br) from wiring harness (13) to brown lead (br) from standard wiring harness.
Use solder connectors.