ME-SFI secondary air injection malfunction (causal chain) - fault code description - AD07.61-P-4000-15M
| Air injection malfunction (causal chain) | ||
|---|---|---|
| 1 | Fault code | P2003 (P0410) |
| (Fault code according to OBD) | P2028 Right cylinder bank (P0410) P2029 Left cylinder bank (P0410) |
|
| 2 | Fault storage | After expiry of test duration and fault |
| Actuation of indicator lamp for engine diagnosis (EURO4) or CHECK ENGINE (MIL) |
Following two successive driving cycles with faults P2028, P2029: No actuation for EURO4 |
|
| 3 | Checking frequency | once per driving cycle |
| 4 | Checked signal or status | Lambda control |
| 5 | Fault setting conditions | Increase of lambda regulation factor by at least +25% ("rich" stop) |
| Checking duration | Approx. 10 seconds | |
| 6 | Check prerequisites |
|
| 7 | Check procedure | On starting the causal chain, all functions for self-regulation of mixture adjustment are locked, the switchover valve for regeneration is closed and the current lambda controlling factor recorded. This is followed by air injection. The mixture must be made leaner. The lambda control factor reacts in a corresponding manner with an increase of more than +25 %. |
| 8 | If a prerequisite changes during the test, the test is interrupted and started again later. A fault is also issued of actuation of the electric air pump is faulty. |