Washer nozzles/washer nozzle hose heater, function - GF82.35-P-3003R
MODEL 230
Function
The washer nozzle heater (R2/1) and the washer fluid hose heater (R2/11) are automatically switched on if:
- Circuit 61 ON (engine running) and
- an outside temperature below 5°C is detected.
Switch off is accomplished automatically when:
- Term. 61 OFF (motor OFF) or
- an outside temperature above 8°C is detected.
Actuation of heating elements
The washer nozzle heater (R2/1) and the washer nozzle hose heater (R2/11) are actuated by the passenger-side SAM control unit (N10/11).
| Outside temperature sensor, location/task/design/function | GF83.57-P-2103R | ||
| Driver-side SAM control unit with fuse and relay module, location/task/design | GF54.21-P-4109R | ||
| Passenger-side SAM control unit with fuse and relay module, location/task/design | GF54.21-P-4111R | ||
| Electronic ignition switch control unit location/task/design | GF80.57-P-4116R |