Automatic one-touch up/down feature, function - GF72.29-P-3007S
MODEL 220
Function prerequisites
- Voltage not too low or too high and
- Circuit 15 ON or circuit 15R ON
- Power window synchronized
- Function not disabled, version coding
Function
The automatic one touch up/down feature is triggered by momentarily pressing the power window switch past the first catch point in direction "close" or "open". The corresponding door control module (N69/1, N69/2, N69/3 orN69/4) reads in the switch state and actuates the power window motor (M10/3, M10/4, M10/5 or M10/6 ) until it recognizes via the position recognition that the window is completely closed or open.
If the window is not synchronized
the manual opening/closing mode
is used instead of the automatic one touch up/down feature.
Function interruption
The automatic one touch up/down feature is interrupted when
- the power window switch is actuated again or
- the pinch protection is actuated as the window closes or
- the function prerequisites are no longer fulfilled.
| Position recognition, power windows, function | GF72.29-P-4000S | ||
| Manual opening/closing, function | GF72.29-P-3006S | ||
| Synchronizing power windows, function | GF72.29-P-4003S | ||
| Pinch protection, power windows, function | GF72.29-P-4004S | ||
| Left front door control module, location/purpose/design/function | GF72.29-P-4105S | ||
| Right front door control module, location/purpose/design/function | GF72.29-P-4106S | ||
| Rear door control module, location/purpose/design/function | GF72.29-P-4102S | ||
| Front power window motor, location/function | GF72.29-P-4108S | ||
| Rear power window motor, location/function | GF72.29-P-4109S |