LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2004 >> ML500 >> Repair and Diagnosis >> Engine Mechanical >> Exhaust >> Exhaust Manifolds, Emission Control -- 163 Chassis >> Basic Knowledge >> Air pump switchover valve function - GF14.30-P-3103-03A

Air pump switchover valve function - GF14.30-P-3103-03A

Fig 1: Identifying Air Pump Switchover Valve Components
G04606196

When actuating, the anchor plate (a) is pulled by the solenoid (d) and the sealing rubber (f) closes the aeration. The connection between port 2 and port 3 is opened. So that the vacuum from the intake manifold is built up to the aspirator shutoff valve. In the de-energized state the connection between port 1 and port 3 is re-established and air is thus admitted to port 3.

Fig 2: Identifying Air Admission, Vacuum Supply From Intake Manifold & Connection To Aspirator Shutoff Valve
G04606197