LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2004 >> G55 >> Repair and Diagnosis >> Restraints >> Seat Belts >> Seats & Restraints -- Testing & Repair -- G-Class (463) >> Testing & Repair >> Ignition of removed emergency tensioning retractors - AR91.40-P-0611-02A

Ignition of removed emergency tensioning retractors - AR91.40-P-0611-02A

DANGER Risk of injury  caused by performing testing or repair work on airbag or emergency tensioning retractor units. Store airbag unit with expulsion area on top, do not subject to temperatures above 100 °C.
Interrupt power supply when working on such units
Except model 202 up to 30.6.93
AS91.00-Z-0001-01A
DANGER Risk of injury  caused by performing testing or repair work on airbag or emergency tensioning retractor units. Store airbag units with deployment side toward top, do not expose to temperatures above 100 °C. When working on these units, disconnect current supply and disconnect airbag (AB) with emergency tensioning retractor test connector/connector (X11/13) Model 202 up to 30.6.93 AS91.00-Z-0001-01B
REFER TO GENERAL INFORMATION Notes on controlled deployment of airbag, sidebag and emergency tensioning retractor units Model 163, 164, 168, 170, 199, 202, 203, 208, 209, 210, 215, 220, 230, 240, 251, 414, 461, 463, not valid for AUSTRIA ONLYMWITZERLAND ONLYGERMANY ONLY AH91.60-P-0611-02P
REFER TO FORMS Notes on disposing of airbag and emergency tensioning retractor units All models OS91.00-P-0001-01A
Fig 1: Identifying Deployment Device Components
G07742458Courtesy of MERCEDES-BENZ USA

Using the deployment device 

  1. Insert 2-pin plug connection (8) on the unit to be scrapped.
  2. Dial the rotary switch (4) to position "1".
  3. Press the battery control pressure switch (2) and deployment pressure switch (3) simultaneously.

    IMPORTANT Keep a distance of 10 m for safety.

    IMPORTANT After a successful deployment, the deployment indicator lamp (5) flashes.