LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2004 >> G55 >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC Testing & Repair -- G-Class (463) >> Testing & Repair >> Remove and install air plenum chamber and water collector - AR83.10-P-9998GM

Remove and install air plenum chamber and water collector - AR83.10-P-9998GM

MODEL 463.202 /222 /236 /237 /243 /244 /245 /246 /247 /248 /249 /250 /254 /270 /271 /303 /306 /309 /322 /323 /332 /333 /336 /340 /341 /346 

Fig 1: Identifying Air Plenum Chamber And Water Collector Components (1 Of 2)
G07740665Courtesy of MERCEDES-BENZ USA
Fig 2: Identifying Air Plenum Chamber And Water Collector Components (2 Of 2)
G07740666Courtesy of MERCEDES-BENZ USA
REMOVINGINSTALLING Remove/Install     
1 Open engine hood IMPORTANT See Operating Instructions  
2 Remove bolts (1)    
3 Open hose clamp (2)    
4 Remove water drain hose (3)    
5 Remove fender liner (5) IMPORTANT The water drain hose (3) must be accessible.  
6 Unscrew nut (7)    
7 Remove hose clamp (8)    
8 Remove air plenum chamber and water collector (9) IMPORTANT Remove with water drain hose (3) upwards.
IMPORTANTInstallation:  Grease bolt (10) lightly. Ensure that the bolt (10) is correctly seated in the guide.
 
INSPECT Check     
9 Check gasket (11) for damage IMPORTANT Replace, if necessary.  
10 Install in the reverse order