Connect compression tester - AR01.10-P-0010-01GV
| Information on preventing damage to electronic components due to electrostatic discharge | AH54.00-P-0001-01A |
- Remove control unit box cover (1).
- Clip connection terminal (A) of compression tester onto circuit 30, 15, 61 terminal block (3-pin) (X12/3).
- Disconnect connector at control unit box/engine separation point (X35/63).
Connect adapter line (2) with pin 6 of control unit box/engine separation point (X35/63).
Connect adapter line (2) to the cable of the compression tester.