LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2004 >> E500 Base >> Repair and Diagnosis >> Accessories & Equipment >> Infotainment >> Electrical System, Equipment & Instructions - Retrofitting & Conversion - 211 Chassis - 1 Of 2 >> Retrofitting & Conversion >> Retrofit ultrasonic back-up assist - AZ54.65-P-0001 >> Retrofit ultrasonic back-up assist - AZ54.65-P-0001T >> Installing and connecting sensors - AZ54.65-P-0001-03T

Installing and connecting sensors - AZ54.65-P-0001-03T

  1. Clip sensor holder (10) into ram strip (13).
    Fig 1: Identifying Sensor Holder Into Ram Strip
    G04984469
  2. Clip sensors (12) into sensor holder (10) so that the connecting coupling (arrow) is inside pointing to the center of the ram strip.

    IMPORTANT The right-hand sensors with the coupling pointing to the left and the left hand sensors with the coupling pointing to the right.

    Fig 2: Locating Connecting Coupling
    G04984470
  3. Install ram strip in bumper and connect bumper wiring harness (1) to sensors (12).

    IMPORTANT The connecting coupling with the grommet must be on the left-hand side of the bumper.

  4. Hook the wiring harness (1) into the holder provided on the bumper.
    Fig 3: Identifying Bumper Wiring Harness
    G04984471
  5. Attach the supplied retaining clips (14) in the bumper and fasten the wiring harness (1).
    Fig 4: Identifying Retaining Clips
    G04984472