Home >> Mercedes Benz >> 2004 >> CLK320 2D Convertible >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Electrical System, Equipment & Instructions -- Testing & Repair - 209 Chassis >> Testing & Repair >> Check quiescent current consumption - AR54.10-P-1030P >> Preparing test without quiescent current retention unit - AR54.10-P-1030-02P

Preparing test without quiescent current retention unit - AR54.10-P-1030-02P

Fig 1: Identifying Electrical Connection Set (201 589 00 99 00)
G04733783Courtesy of MERCEDES-BENZ USA
COMMERCIALLY AVAILABLE TOOLS

Number Designation
WH58.30-Z-1001-09A Multimeter
  1. Slacken nut on negative battery terminal clip.

    IMPORTANT Do not disconnect the negative terminal clip!

  2. Prepare multimeter (2) for the test using SPECIAL TOOL electrical connection set.
  3. Connect positive test cable (+) to negative battery cable (1).
  4. Switch on multimeter (measuring range in amperes).
  5. Fig 2: Identifying Multimeter With Measurement Cable And Battery Ground Point
    G04733784Courtesy of MERCEDES-BENZ USA
  6. Carefully pull up negative battery terminal clip and at the same time connect negative test cable (-) under terminal clip on negative terminal (3).

    IMPORTANT Do not break the circuit when pulling off the negative terminal clip otherwise any existing faults will be erased. Remove the negative terminal clip completely only after the multimeter test cable is firmly connected to the negative terminal.

  7. Route multimeter (2) with measurement cable (6) out of the engine compartment (on models 203, 209) / passenger compartment (on model 463).
    Fig 3: Identifying Multimeter And Measurement Cable
    G04733785Courtesy of MERCEDES-BENZ USA