Acoustic alarm, function - GF80.50-P-4005D
MODEL 129, 170 as of 1.6.98 with CODE (551a) Anti-theft alarm (ATA)
The acoustic alarm is triggered automatically by the alarm signal siren with additional battery (H3/1) . The sequence of the acoustic signals can differ depending on how the alarm was triggered and which country is coded in the alarm signal siren with additional battery (H3/1).
- ECE:
30 seconds short acoustic signals
:
60 seconds short acoustic signals
30 seconds pause
60 seconds short acoustic signals
The siren coding can be programmed with the version coding for the ATA.
- The alarm can be terminated by activating or deactivating the ATA.
- The alarm cannot be interrupted by disconnecting the connection leads to the alarm signal siren with additional battery (H3/1)!
- The alarm sequence can deviate from the coding when the connection between the alarm signal siren and PSE control module is interrupted.
| Alarm signal siren, location/purpose/design/function | GF80.50-P-4110A | ||
| Optical alarm, function | GF80.50-P-4006D |