Arrangement and assignment of Z connector sleeves (solder splices in wiring harness) trunk (left) - GF00.19-U-3000-06KA
MODEL 230
Fig 1: Identifying Arrangement And Assignment Of Z Connector Sleeves (Solder Splices In Wiring Harness) Trunk (Left)
| Z connector sleeve | Designation | Component | Designation | Connector Pin |
|---|---|---|---|---|
| Z7/49 | KEYLESS-GO 24 V supply connector sleeve | ← N69/5 | KEYLESS GO control unit | 4.2 |
| → A2/38 | Left door KEYLESS-GO antenna | 6 | ||
| → A2/40 | Right door KEYLESS-GO antenna | 6 | ||
| Z28/35 | Door handle voltage supply connector sleeve (KEYLESS-GO) | ← N69/5 | KEYLESS GO control unit | 4.12 |
| → S47x1 | Capacitive sensor and push contact connector | 4 | ||
| → S48x1 | Capacitive sensor and push contact connector | 4 | ||
| Z36/1 | Rear PTS sensor ground connector sleeve | ← N62 | PTS control module | 1.8 |
| → A43b7 | Right outer sensor | 2 | ||
| → A43b8 | Right inner sensor | 2 | ||
| → A43b9 | Left inner sensor | 2 | ||
| → A43b10 | Left outer sensor | 2 | ||
| Z36/2 | Rear PTS sensor voltage supply connector sleeve | ← N62 | PTS control module | 1.28 |
| → A43b7 | Right outer sensor | 4 | ||
| → A43b8 | Right inner sensor | 4 | ||
| → A43b9 | Left inner sensor | 4 | ||
| → A43b10 | Left outer sensor | 4 |