Regeneration system leaking (causal chain) ME-SFI - fault code description - AD07.61-P-4000-17M
| 1 | Fault code | P2013 Major leak in purge system (P0455) |
| (Fault code according to OBD) | P2014 Minor leak in purge system, a minor leak (P0422) P2015 Purge control system has leak (function chain) (P0440) P2075 Minor leakage in purge system, micro leakage (P0446) |
|
| 2 | Fault storage | After expiry of test duration and fault |
| Actuation CHECK ENGINE indicator lamp (MIL) |
Following two successive driving cycles with faults | |
| 3 | Checking frequency | Once per driving cycle |
| 4 | Checked signal or status | Change in speed of pressure values at the tank pressure sensor |
| 5 | Fault setting conditions | |
| Major leakage in purge system | Vacuum build-up of approx. 0.8 mbar per second is not achieved | |
| Minor leakage in purge system, Minor leakage ≥ 1 mm | For a closed system the vacuum should not decrease more rapidly than 0.3 to 0.7 mbar per second (dependent on fuel level). | |
| Minor leakage in purge system, micro leakage, ≥ 0.5 mm | For a closed system the vacuum should not decrease more rapidly than 0.1 to 0.15 mbar per second (dependent on fuel level). | |
| Checking duration | A maximum of 30 s for testing for major and minor leakages At least 50 seconds for checking for a micro leak |
|
| 6 | Check prerequisites |
|
| 7 |
|
Any checks for leaks must be capable of detecting leaks from as small as 0.5 mm in the purge system. To do this a pressure test is carried out with the engine idling and with the vehicle stationary
Testing takes place in three stages:
- Test for major leaks
- Test for a minor leak (equal to or greater than 1 mm)
- Test for a micro leak (equal to or greater than 0.5 mm)
Test for major leaks
The activated charcoal canister shut-off valve (Y58/4) is closed and the purge control valve (Y58/1) opened. The intake manifold vacuum flows to the fuel tank and a vacuum builds up in the fuel tank. This is detected by the fuel tank pressure sensor (B4/3).
If there is no vacuum build-up in the fuel tank (approx. -6 mbar within approx. 15 seconds), there is a major leak (e.g. fuel tank cap open, loose hose line). The diagnosis is terminated and the fault major leak in purge system is stored.
If the ME-SFI [ME] control unit recognizes a major leak in the system, the fuel reserve warning lamp in the instrument cluster flashes and "CHECK FILLER CAP" appears in the multifunction display.
Test for a minor leak
The purge control valve (Y58/1) is closed once a certain vacuum exists (approx. -6 mbar). The system is now likewise closed. The vacuum is them measured for approx. 30 seconds. It must not drop any faster than 0.3 to 0.5 mbar per second (depending on the level of fuel in the tank). If the vacuum drops more rapidly, there is a minor leak.
Check for micro leakage
If no minor leak has been detected, the purge system is briefly enabled and a vacuum of approx. -6 mbar is built up again. The vacuum must not drop any faster than 0.1 to 0.15 mbar per second for a closed system (depending on the level of fuel in the tank).
The reduction in the vacuum depends on the fill level in the fuel tank and on the degassing of the fuel. Degassing of the fuel is measured for a short time prior to the test and is allowed for in the fault statement. No test is conducted during the driving cycle if the fuel tank is filled to less than 30 %.
The activated charcoal canister shut-off valve (Y58/4) is reopened after the tests have been conducted.