Check quiescent current consumption - AR54.10-P-1030I: Notes

MODEL 215, 220, 230 

  Check     
1 Open luggage compartment lid    
2.1 Preparing test with quiescent current retention unit   AR54.10-P-1030-01I 
    SPECIAL TOOL Electrical connection set Figure
    COMMERCIALLY AVAILABLE TOOLS Multimeter *WH58.30-Z-1001-09A 
    COMMERCIALLY AVAILABLE TOOLS Quiescent current retention unit CMP 12.2 *WH58.30-Z-1012-09A 
2.2 Prepare test without quiescent current retention unit   AR54.10-P-1030-02I 
    SPECIAL TOOL Electrical connection set Figure
    COMMERCIALLY AVAILABLE TOOLS Multimeter *WH58.30-Z-1001-09A 
3 Switch off all consumers
  • Withdraw ignition key
  • Switch off stationary heater
  • Switch off car phone
  • Switch off interior motion sensor
  • Switch off make-up mirror
  • Switch off reading light
  • Turn exterior lamp switch to "0" position
  • Close doors

IMPORTANT The interior lights must go out automatically after a few seconds.
  • Switch off radio
  • With COMAND:

    Remove CD-ROM from COMAND and switch off COMAND.

 
4 Check quiescent current AR54.10-P-1030-03I   
    SPECIAL TOOL Electrical connection set Figure
    COMMERCIALLY AVAILABLE TOOLS Multimeter
If specification for total quiescent current is not achieved: ↓
*WH58.30-Z-1001-09A 
    Determine circuit with excessive quiescent current consumption AR54.10-P-1030-04I 
    SPECIAL TOOL Electrical connection set Figure
    SPECIAL TOOL Quiescent current test adapter 1 Figure
    SPECIAL TOOL Quiescent current test adapter 2 Figure
    COMMERCIALLY AVAILABLE TOOLS Multimeter
Specification not achieved: ↓
*WH58.30-Z-1001-09A 
    Establish fused components with excessive quiescent current consumption AR54.10-P-1030-05I 
    SPECIAL TOOL Electrical connection set Figure
    SPECIAL TOOL Quiescent current test adapter 1 Figure
    SPECIAL TOOL Quiescent current test adapter 2 Figure
    COMMERCIALLY AVAILABLE TOOLS Multimeter
Specification not achieved: ↓
*WH58.30-Z-1001-09A 
    Establishing unfused components with excessive quiescent current consumption AR54.10-P-1030-06I 
    SPECIAL TOOL Electrical connection set Figure
    COMMERCIALLY AVAILABLE TOOLS Multimeter *WH58.30-Z-1001-09A 
    To check, re-test quiescent current AR54.10-P-1030-03I 
    SPECIAL TOOL Electrical connection set Figure
    COMMERCIALLY AVAILABLE TOOLS Multimeter *WH58.30-Z-1001-09A 
Fig 1: Identifying Electrical Connection Set (201 589 00 99 00)
G04849695
Fig 2: Identifying Quiescent-Current Test Adapter 1 (140 589 12 21 00)
G04849696
Fig 3: Identifying Quiescent Current Test Adapter 2 (140 589 13 21 00)
G04849697
COMMERCIALLY AVAILABLE TOOLS

Number Designation
WH58.30-Z-1001-09A Multimeter
WH58.30-Z-1012-09A Quiescent current retention unit