Correct oil level in air conditioning system after replacing parts - AR83.30-P-5252GM
MODEL 461.302 /304 /305 /331 /332 /333 /334 /340 /342 /343 /344 /345 /346
MODEL 463.202 /222 /236 /237 /243 /244 /245 /246 /247 /248 /249 /250 /254 /270 /271 /303 /306 /309 /322 /323 /332 /333 /336 /340 /341 /346
| Picture item, etc. | Work instructions | ||
| Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | AS83.00-Z-0001-01A | |
| Procedure for a damaged or leaky air conditioning system | All models | AH83.30-N-0004-01A | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models with air conditioning | AH83.30-N-0005-01A | |
| Notes on handling R134a refrigerant | Air conditioning with refrigerant R134a | AH83.30-N-0003-01A | |
| Correct oil level in air conditioning system when replacing AC compressor | AR83.55-P-5250GM | ||
| Replenishing quantity when replacing condenser | *BF83.30-P-1003-01A | ||
| Replenishing quantity when replacing receiver | *BF83.30-P-1004-01A | ||
| Refill volume when replacing a refrigerant line | *BF83.30-P-1005-01A | ||
| Replenishing quantity if air conditioning system suddenly drained (line fracture) | *BF83.30-P-1006-01A |
AIR CONDITIONING
| Number | Designation | Model 461.305/333/340/343 | ||
|---|---|---|---|---|
| BF83.30-P-1003-01A | Compressor oil refill quantity when replacing condenser | cm3 | 20 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0361-00A | ||
| BF83.30-P-1004-01A | Refill quantity of compressor oil when replacing the accumulator | cm3 | 10 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0361-00A | ||
| BF83.30-P-1005-01A | Refill quantity of compressor oil when replacing a coolant line | cm3 | 10 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0361-00A | ||
| BF83.30-P-1006-01A | Compressor oil refill quantity when air conditioning system is suddenly evacuated (line break) | cm3 | 40 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0361-00A | ||
AIR CONDITIONING
| Number | Designation | Model 461.302/304/331/332/334/342/344/345/346 | ||
|---|---|---|---|---|
| BF83.30-P-1003-01A | Compressor oil refill quantity when replacing condenser | cm3 | 20 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0361-00A | ||
| BF83.30-P-1004-01A | Refill quantity of compressor oil when replacing the accumulator | cm3 | 10 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0361-00A | ||
| BF83.30-P-1005-01A | Refill quantity of compressor oil when replacing a coolant line | cm3 | 10 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0361-00A | ||
| BF83.30-P-1006-01A | Compressor oil refill quantity when air conditioning system is suddenly evacuated (line break) | cm3 | 40 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0361-00A | ||
AIR CONDITIONING
| Number | Designation | Model 463.206/209/232/233/240/243/244/245/246/247/249/250/254/270/271, Model 463.241/248 without code HH7 | Model 463.236/241/248 with code HH7 | ||
|---|---|---|---|---|---|
| BF83.30-P-1003-01A | Compressor oil refill quantity when replacing condenser | cm3 | 20 | 20 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0362-00A | BB00.40-P-0362-00A | ||
| BF83.30-P-1004-01A | Refill quantity of compressor oil when replacing the accumulator | cm3 | 10 | 10 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0362-00A | BB00.40-P-0362-00A | ||
| BF83.30-P-1005-01A | Refill quantity of compressor oil when replacing a coolant line | cm3 | 10 | 10 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0362-00A | BB00.40-P-0362-00A | ||
| BF83.30-P-1006-01A | Compressor oil refill quantity when air conditioning system is suddenly evacuated (line break) | cm3 | 40 | 40 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0362-00A | BB00.40-P-0362-00A | ||
AIR CONDITIONING
| Number | Designation | Model 463.322/323 | Model 463.309/332/333 | ||
|---|---|---|---|---|---|
| BF83.30-P-1003-01A | Compressor oil refill quantity when replacing condenser | cm3 | 20 | 20 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0362-00A | BB00.40-P-0362-00A | ||
| BF83.30-P-1004-01A | Refill quantity of compressor oil when replacing the accumulator | cm3 | 10 | 10 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0362-00A | BB00.40-P-0362-00A | ||
| BF83.30-P-1005-01A | Refill quantity of compressor oil when replacing a coolant line | cm3 | 10 | 10 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0362-00A | BB00.40-P-0362-00A | ||
| BF83.30-P-1006-01A | Compressor oil refill quantity when air conditioning system is suddenly evacuated (line break) | cm3 | 40 | 40 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0362-00A | BB00.40-P-0362-00A | ||
AIR CONDITIONING
| Number | Designation | Model Model 463.202/222/236/237/303/306/336/340/341/346 |
||
|---|---|---|---|---|
| BF83.30-P-1003-01A | Compressor oil refill quantity when replacing condenser | cm3 | 20 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0362-00A | ||
| BF83.30-P-1004-01A | Refill quantity of compressor oil when replacing the accumulator | cm3 | 10 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0362-00A | ||
| BF83.30-P-1005-01A | Refill quantity of compressor oil when replacing a coolant line | cm3 | 10 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0362-00A | ||
| BF83.30-P-1006-01A | Compressor oil refill quantity when air conditioning system is suddenly evacuated (line break) | cm3 | 40 | |
| Specifications for Operating Fluids | Sheet | BB00.40-P-0362-00A | ||