LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2003 >> E500 >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Electrical System, Equipment & Instructions - Trouble Diagnosis - 211 Chassis >> Trouble Diagnosis >> Error message in instrument cluster in red lettering at high outside temperatures and faults codes 9050 and 9051 are stored in the battery control unit - AF54.10-P-8030A

Error message in instrument cluster in red lettering at high outside temperatures and faults codes 9050 and 9051 are stored in the battery control unit - AF54.10-P-8030A

MODEL 211.### ## up to 350386 

Operation no. of operation texts or standard texts and flat rates 

OPERATION NO. OF OPERATION TEXTS OR STANDARD TEXTS AND FLAT RATES

Category Op. no. Operation text Time Acc. no. Code
P 541011 Perform quick test 004 WU - -
P 542300 Replace control unit for on-board electrical system (after testing), MODEL 211.0 009 WU - -
P 542300 Replace control unit for on-board electrical system (after testing), MODEL 211.2 012 WU - -
Damage code Cause Remedy  
54 849 73 Battery control unit (BSG) 1 Check Q-status and part number of battery control unit (BSG).  
  IMPORTANT At high temperatures (more than 50°C) in the spare wheel well, unstable conditions can occur for the battery control unit (BSG). IMPORTANT As of VIN end no. 350387 temperature tested battery control units with a software release of Q1  
  The BSG cannot display any voltage or current values in these conditions. (A 211 540 27 45) and with a white HT stamp on the housing are installed in the series production.  
  The following fault messages could be shown in red lettering in the instrument cluster (KI): IMPORTANT As of VIN end number 363850 temperature tested battery control units with a new software release of Q2  
 
  • "Stop! Battery/Alternator"
(A 211 540 27 45) are being installed in the series production.  
 
  • "Brake defective! Stop the vehicle!"
The white stamp on the housing is now omitted.  
  IMPORTANT Furthermore, fault codes 9050 and 9051 for consumer shutoff stages 1 and 2 are stored in the battery control unit. IMPORTANT If a battery control unit (BSG) is installed with an older Q-status:
↓
2 Remove/install/replace battery control unit (BSG).
 
PARTS ORDERING NOTES

Part no. Designation Quantity
A 211 540 27 45 Battery control unit as required