LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2003 >> E500 >> Repair and Diagnosis >> Brakes >> Mechanical - Hydraulic >> Brakes - Testing & Repair - 211 Chassis >> Testing & Repair >> Remove/install electronic stability program (ESP) control unit - AR42.45-P-0820 >> Remove/install electronic stability program (ESP) control unit - AR42.45-P-0820TA >> Detach/mount connector - AR42.45-P-0820-02T

Detach/mount connector - AR42.45-P-0820-02T

Connector on ESP control unit 

Fig 1: Identifying Electrical Connector
G04984034

Disconnect electrical connector 

NOTES In the event of damage to the bracket (1), connector (2) or connector locking mechanism it is essential to replace the appropriate pars, otherwise the connector (2) can detach from the control unit (N47-5).

  1. Open the connector locking mechanism; to do this, press both release buttons (1e) carefully from the bottom upwards.

    IMPORTANT Do not use a tool Do not open snap-in bracket (1n)

  2. Swivel bracket (1) upwards approx. 90°.

    IMPORTANT The connector (2) is pushed slightly out of the jack (3) on the control unit (N47-5).

  3. Pull connector (2) out of jack (3).

    NOTES In the process do not handle the connector (2) at the bracket (1), otherwise damage to the bracket (1) and connector locking mechanism can occur

  4. Swivel bracket (1) downwards until the connector locking mechanism latches.

    IMPORTANT In order to avoid damage to the bracket (1) and connector locking mechanism.

    Connect electrical connector 

  5. Open connector locking mechanism (see operation step  1).
  6. Swivel bracket (1) upwards approx. 90°.
  7. Insert connector (2) in jack (3) on control unit (N47-5) until this contacts the base of the jack (3) evenly over its entire length.

    NOTES In the process do not handle the connector (2) at the bracket (1), otherwise damage to the bracket (1) and connector locking mechanism can occur

  8. Swivel bracket (1) downwards until the connector locking mechanism latches.

    IMPORTANT The connector (2) is drawn into its end position and locked.