Remove contacts from FIN sensor contact coupling - AR00.19-P-0120-12A

WARNING: This page does not describe the selected car, but rather 11 other vehicles, including the 2014 Mercedes-Benz C63 AMG, 2013 Mercedes-Benz C63, 2012 Mercedes-Benz C63, 2011 Mercedes-Benz C63, and 2011 Mercedes-Benz C350. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Identifying New Passenger Vehicle Wiring Harness Repair Kit (220 589 04 99 00)
G07529804Courtesy of MERCEDES-BENZ USA
Fig 2: Identifying Wiring Harness Repair Kit Basic (000 589 13 99 00)
G07529805Courtesy of MERCEDES-BENZ USA
Fig 3: Identifying Blade Holder With Clamping Pliers (220 589 01 99 50)
G07529806Courtesy of MERCEDES-BENZ USA
Fig 4: Identifying LSK 8 Blade (220 589 01 99 56)
G07529807Courtesy of MERCEDES-BENZ USA

Unfasten secondary release on version with spring (shown on laminated sensor contact, Junior Power Timer coupling) 

  1. Insert a suitable tool between the spring and the housing.
  2. Press out the spring.
    Fig 5: Inserting Suitable Tool Between Spring And Housing
    G07529808Courtesy of MERCEDES-BENZ USA

    Unfasten secondary release on version with slide (shown on laminated sensor contact, Junior Power Timer coupling) 

  3. Push (1) slider out of locked position in direction of arrow.
    Fig 6: Pushing Slider Out Of Locked Position
    G07529809Courtesy of MERCEDES-BENZ USA

    Unfasten secondary release on version with pin 

  4. Using a suitable tool, push pin out of last detent in direction shown by arrow.
    Fig 7: Pushing Pin Out Of Last Detent
    G07529810Courtesy of MERCEDES-BENZ USA

    Unpin female contacts from coupling 

  5. Insert blade holder with SPECIAL TOOL clamping pliers and SPECIAL TOOL LSK 8 blade from front side though openings at contact cavity of coupling (1).

    IMPORTANT This step compresses the spring shackles (2) on the female contact.

  6. A slight tug on the corresponding cable will remove the female contact (1) from the coupling.
    Fig 8: Inserting Blade Holder From Front Side Though Openings At Contact Cavity Of Coupling
    G07529811Courtesy of MERCEDES-BENZ USA