Notes on crimping - AH00.19-P-1000-09A
- Check crimped connections for correct forming and filling (cross-section, ensure that leads are enclosed correctly).
Correct crimped connection (A):
The strands of the cable are evenly enclosed.
The crimp tab is evenly shaped.
Incorrect crimped connection (B):
The crimp tab has an incorrect cross-section and is not full enough.
Incorrect crimped connection (C):
Individual wire strands are outside the crimp shackle.
The crimp tab is too full.
Incorrect crimped connection (D):
The crimp claws touch the bottom of the crimped fitting.
The crimp tab is too full.
The crimp tab is deformed and therefore damaged.
Shown with circular conductor
- 2a Check crimped connection without single-strand insulation (ensure that all lines are enclosed correctly).
Correct crimped connection (A):
Leads (3) enclosed correctly by the tab (2).
Insulation is enclosed correctly by the tab (1).
Incorrect crimped connection (B, C):
Leads (3) are damaged due to deformed tab (2).
Insulation is pinched by deformed tab (1) and damaged.
- 2b Check crimped connection with single-strand insulation (ensure that all lines are enclosed correctly).
Insulation and single-strand insulation must be positioned in the center and enclosed completely by the crimp tab and they must be able to take up tensile force.
Single-strand insulation must not be pinched otherwise contact corrosion can occur if the connection is penetrated by water.
Correct crimped connection (A):
Wire strands are enclosed correctly by the shackle. Insulation and single-strand insulation are enclosed correctly by the large tab. All parts can withstand the required tensile force.
Incorrect crimped connections (B, C):
The single-strand insulation is not enclosed by the shackle because it was inserted incorrectly during the crimping procedure.
The crimped area of the single-strand insulation is damaged because the wrong die set or wrong single-strand insulation was used.
- 3a Check crimped connection without single-strand insulation (ensure that leads and insulation are of correct length).
Correct crimped connection (A):
Correct length of insulation is enclosed by the shackle (1).
Wires (3) are the correct length in the tab (2).
Incorrect crimped connection (B):
Insulation is too short and is not correctly enclosed by the tab (1).
Therefore insulation cannot withstand the required tensile load.
Incorrect crimped connection (C, D):
Wire strands (3) are too long.
Leads (3) are too short.
- 3b Check crimped connection with single-strand insulation (for correct length and distance of leads and insulation, as well as position and condition of seal).
Correct crimped connection (A):
Insulation and wires are of the correct length in the shackles. Correct distance between the single-strand insulation and the end of the insulation.
Incorrect crimped connections (B, C):
The single-strand insulation is damaged because the distance between seal and end of insulation is too small.
Stripped strands are too long, single-strand insulation is therefore not crimped.