Remove/install extinguishing agent tank - AR86.10-P-0100MB
MODEL 220.1 /8 with CODE (Z04) Light armoring with CODE (Z07) Top protection with fire extinguishing system
MODIFICATION NOTES
| 8.5.07 | "Transportation of filled extinguishing agent tanks is only allowed without squibs and with squib opening sealed", added | OS86.10-P-1000-02A |
| Remove/install | |||
| Special notice regarding wax preservative | AH97.20-P-1000-02PV | ||
| Notes on aerosol extinguishing agent tank | AH86.10-P-0001-02A | ||
| Notes for extinguishing agent tank pressure monitor switch | AH86.10-P-0001-03A | ||
| 1 | Switch off ignition, detach transmitter key from electronic ignition switch control unit | ||
| 2 | Remove fuses no. 54 and no. 58 in rear fuse and relay module | ||
| Fuse assignment of rear fuse and relay box | GF54.15-P-1256-01MB | ||
| 3 | Remove paneling from extinguishing agent tank (1). | AR86.10-P-0103MB | |
| 4 | Disconnect electric lead from squib (7). | ||
| 5 | Disconnect fire extinguishing tank 1 pressure monitor connector (S62/27x1) and fire extinguishing tank 2 pressure monitor connector (S62/28x1) | ||
| 6 | Unscrew union nuts (6) and remove extinguishing agent tubing (5) | ||
| 7 | Loosen clamps (2) and remove extinguishing agent tank (1). | ||
| 8 | Check weight of extinguishing agent tank (1). | ||
| Notes on disposing aerosol extinguishing agent tank | OS86.10-P-1000-02A | ||
| 9 | Install in the reverse order | ||
| 10 | Perform self-test for fire extinguishing system | AR86.10-P-0101-01MB |