Central locking of driver's door, testing pneumatics, PSE - AD80.20-P-8000-01A
Vacuum supply
| Scope of test | Measuring instrument/Test connection | Operation/Requirement | Specified value |
|
|
| 1.0 | Central locking of driver's door (vacuum supply) | Seal remaining pneumatic connections on PSE with rubber caps. | ≥ 450 mbar in ≤ 1.2 seconds |
AD80.20-P-6001-01A AD80.20-P-6001-01B |
|
| Close doors. | AD80.20-P-6001-01C | ||||
| Note on test connection: | |||||
| Driver's door connection on PSE black connection on tester | Lock vehicle via interior switch (CL). |