Lines, testing pneumatics, CL - AD80.20-P-8001-08B
Vacuum range
| Scope of test | Measuring instrument/Test connection | Operation/Requirement | Specified value |
|
|
| 1.0 | Leaktightness in vacuum range | Evacuate pneumatic line to vacuum of 300 mbar | Pressure increase 0 mbar in 1 minute |
|
|
| Note on test connection: black connection on tester |