LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2002 >> SLK230 Automatic >> Repair and Diagnosis >> Body & Frame >> Ignition Switch/Steering Lock >> Anti-Theft & Central Locking System -- 170 Chassis >> Self-Diagnostic System >> Central locking (CL), testing pneumatics - AD80.20-P-8001A >> Lines, testing pneumatics, CL - AD80.20-P-8001-08B

Lines, testing pneumatics, CL - AD80.20-P-8001-08B

Vacuum range 

HAND-HELD TESTER Scope of test Measuring instrument/Test connection Operation/Requirement Specified value
  • Possible cause/Remedy
1.0  Leaktightness in vacuum range    Evacuate pneumatic line to vacuum of 300 mbar Pressure increase 0 mbar in 1 minute
  • Pneumatic line leaking: repair or replace
  Note on test connection: 
black  connection on tester