LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2002 >> SLK230 Automatic >> Repair and Diagnosis >> Body & Frame >> Ignition Switch/Steering Lock >> Anti-Theft & Central Locking System -- 170 Chassis >> Basic Knowledge >> Alarm triggered by exterior surface contact, function - GF80.50-P-3015D

Alarm triggered by exterior surface contact, function - GF80.50-P-3015D

MODEL 170 with CODE (551a) Anti-theft alarm (ATA) 

MODEL 170 with CODE (552a) Anti-theft alarm (ATA) for Switzerland 

When the anti-theft alarm (ATA)  is activated actuation of an exterior contact triggers an alarm.

The exterior contacts are:

The switches (S17/3, S17/4, S69/1 and S62) transmit a ground signal  to the PSE control module when doors/trunk lid or hood are open  .

The prerequisite for triggering an alarm is that the alarm input on the PSE control module (combined) (A37)  , to which the corresponding contact is connected, has been armed by activating the ATA  .

IMPORTANT

A triggered alarm can no longer be terminated by resetting the contact, i.e. closing a door opened previously.

REFER TO BASIC KNOWLEDGE Acoustic alarm, function up to 5/98 GF80.50-P-4005B 
    as of 6/98 GF80.50-P-4005D 
REFER TO BASIC KNOWLEDGE Optical alarm, function up to 5/98 GF80.50-P-4006B 
    as of 6/98 GF80.50-P-4006D