Note on airbag fault memory diagnosis - AD91.60-P-2000-05A
The fault is current when the fault code is displayed against a black background.
Depending on the type of fault, detailed information on faults or partial data also appear for most faults
>Ω Resistance too high
<Ω Resistance too low
Short-circuit to -
+ Short-circuit to +
Open-circuit
For most fault codes the following additional information such as fault frequency/operating time can be read out using the button
.
Fault frequency
The number of times a fault has occurred, for example: 5, temporary fault occurred
5 times, disappeared 5 times.
Operating time
The time which has elapsed since a fault occurred.
The time which has elapsed since the fault disappeared.
Actual values
Four displays are possible:
√, F EIN, AUS
√, The respective values are within the specified value.
F The respective values are not within the specified value
EIN Seat belt buckle fastened
, front passenger seat occupied, MB Babysafe child seat recognized
AUS Seat belt buckle not fastened
, front passenger seat not occupied, MB Babysafe child seat not recognized
In contrast to the fault memory, the actual values are constantly updated even during diagnosis so that, for example an intermittent fault can be determined by shaking the components, connectors or wiring harness.
Version of control modules
The following information can be read out for the airbag control modules and the side airbag sensors:
- Model
- Manufacturing location
- Date of manufacture
- Module date code (as of 12/96 module date code only)