Preparing test with quiescent current retention device - AR54.10-P-1030-01AD
Model 170
Commercially available tools
| Number | Designation |
|---|---|
| WH58.30-Z-1001-09A | Multimeter |
| WH58.30-Z-1012-09A | Quiescent current retention unit |
- Connect quiescent current retention device (7) as follows:
- Connect terminal on positive lead (+) to positive pole on battery.
- Connect terminal on negative lead (-) to battery ground (W10).
- Switch on quiescent current retention device (7).
- Disconnect negative pole terminal (1) from battery.
- Connect multimeter (2) with electrical connection set:
- Connect positive test cable (+) to negative lead (1) on battery.
- Connect negative test cable (-) to negative pole (3) on battery.
- Switch on multimeter (2) (amps mode).
- Switch off quiescent current retention device (7) and disconnect.
- Extend test cable (6) out of engine compartment.