Determining circuit with increased quiescent current consumption - AR54.10-P-1030-04C
| Determining circuit with increased quiescent current consumption | |||
| Determine fused components in which quiescent current is too high | AR54.10-P-1030-05AB | ||
| To check test quiescent current again. Nominal value ≤ 0.05 A (50 mA) or 0.09 A: ↓ |
AR54.10-P-1030-03C | ||
| Determine unfused components in which quiescent current is too high | AR54.10-P-1030-06AB | ||
| To check test quiescent current again | AR54.10-P-1030-03C |
| Number | Designation |
|---|---|
| WH58.30-Z-1001-09A | Multimeter |
- Check trunk illumination, if necessary replace damaged part.
Unclip trunk lamp, pull off insulated terminal and measure current with multimeter (amps range). After checking observe after-running time of approx. 10 min. again.
If total current consumption is ≤ 0.05 A or ≤ 0.09 A
(vehicles with alarm system code 551), end of test:
If total quiescent current is not reached: ↓
- Open fuse boxes F1, F4 and light module cover (N7-1).
- On vehicles with ATA, lock engine hood lock with screwdriver.
- Lock vehicle.
- Open cover on overvoltage protection device.
Observe information update (AI)!
Observe information update (AI)!
First check circuits for components listed in the information update.
- Remove fuse for affected component.
Remove fuse for ATA only with vehicle unlocked (alarm signal).
- Connect test cable (6) and test adapter (13) to a second multimeter (12) (amps mode).
- Pull out first fuse and connect second multimeter in its place. Read off quiescent current after waiting 5 seconds.
Quiescent current ≤ 0.02A (20 mA):
The fused circuit is okay.
- Reinstall fuse, wait 5 seconds.
Then check quiescent current for all fuses according to test step 8.
After reinstalling the fuses or the test adapter, the connected components may have an increased quiescent current momentarily; the quiescent current for the radio may be as high as 0.240 A (240 mA). The increased quiescent current consumption is eliminated by switching the radio on and off again.
Quiescent current > 0.02 A (20 mA):
The fused circuit is defective: ↓
Determine fused components for which quiescent current is too high. If nominal value for total quiescent current is still not reached: ↓
Determine unfused components for which quiescent current is too high.