LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2002 >> SL500 >> Repair and Diagnosis >> Accessories & Equipment >> Wiper/Washer Systems >> Electrical System - Body -- 129 Chassis >> Testing & Repair >> Checking pneumatic headlamp range adjustment - AR82.10-P-4011A >> Checking vacuum system of headlamp range adjustment - AR82.10-P-4011-01A

Checking vacuum system of headlamp range adjustment - AR82.10-P-4011-01A

TEST VALUES FOR EXTERIOR LIGHTING

Number Designation Model 129
BE82.10-P-1001-01D Pressure values for pneumatic headlamp range adjustment Position 0 mbar 400 ± 30
Position 1 mbar 290 ± 30
Position 2 mbar 200 ± 30
Position 3 mbar 50 ± 30
Fig 1: Identifying Vacuum Tester (201 589 13 21 00)
G04688569
  1. The pressure for the headlamp range adjustment can be measured on the pressure valve block (4). The pressure valve block (4) is located in the right component compartment.
  2. Allow engine to run.
  3. Set headlamp range adjustment to individual positions and read off pressure values. If the nominal value is not reached, perform leakage test.
    Fig 2: Identifying Pressure Valve Block
    G04688570

IMPORTANT If the connection sockets are leaky they can be replaced by adapters (8). For this purpose separate pneumatic line (9) from control switch (7) and shorten by 50 mm. Install adapter (8) instead of cut connection socket and connect to hose connector (approx. 40 mm long).

Fig 3: Identifying Pneumatic Line, Adapters And Control Switch
G04688571