LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2002 >> G500 >> Repair and Diagnosis >> External Pages >> Different car >> Section 8 (HVAC Basic Knowledge -- G-Class (463) - 2 Of 2) >> Basic Knowledge >> Stationary heater timer, function - GF83.70-G-4007-03A

Stationary heater timer, function - GF83.70-G-4007-03A

WARNING: This page does not describe the selected car, but rather 22 other vehicles, including the 2015 Mercedes-Benz G550, 2014 Mercedes-Benz G550, 2013 Mercedes-Benz G550, 2012 Mercedes-Benz G550, and 2011 Mercedes-Benz G550. However, it is still accessible from the selected car via links, so may be relevant.

Stationary heater timer (N34) (Engine 104 E32, engine 603 D35A, engine 606 D30LA) 

Fig 1: Identifying Stationary Heater Timer Function (Engine 104 E32, Engine 603 D35A, Engine 606 D30LA)
G07740631Courtesy of MERCEDES-BENZ USA

Stationary heater timer (N34) (Engine 102 E30) 

Fig 2: Identifying Stationary Heater Timer Function (Engine 102 E30)
G07740632Courtesy of MERCEDES-BENZ USA

Function 

Stationary heater is manually switched on with "instant heating/instant ventilation" button on timer INSTANT HEAT .

In addition, timer is used for input of programmed switching-on and - off times of stationary heater.

Stationary heater timer 

(valid for engine 104 E32, engine 603 D35A, engine 606 D30LA): 

With stationary heater timer (N34)  three switch-on times with desired weekday can be preset.

Stationary heater timer 

(valid for engine 102 E30): 

With stationary heater timer (N34)  two switch-on times with desired weekday can be preset.

IMPORTANT Without weekday setting, set switching times are valid only within the next 24 hours. Heater operation can be manually interrupted at any time with the "instant heating/instant ventilation" button INSTANT HEAT . After maximum heating time of one hour, timer automatically terminates heater operation.