Apply glue - AR67.10-P-1000-08K

Commercially available tools

Number Designation
WH58.30-Z-1002-20A Electric cartridge gun
  1. When the heat-up time has expired, remove gluing cartridge from cartridge preheater, remove cartridge bottom and perforate diaphragm. Screw on the application nozzle and insert the cartridge into the application gun.

    NOTES Heat-up time min. 20 minutes

  2. Guide nozzle along adhesive surface or residual glue on body flange while pressing a uniform quantity of glue out of the glue cartridge.

IMPORTANT Height of glue bead approx. 13 mm

NOTES Install window within 5 minutes before adhesion of the glue starts decreasing.