Retrofit alarm siren - AN80.50-P-0001-02A
Model 210 as of 01.03.97
Repair materials
| Number | Designation | Order number |
|---|---|---|
| BR00.45-Z-1003-05A | Preservation agent | A 000 986 72 70 05 |
- Install mount (2) to alarm signal siren (H3/1) with bolt (1).
- Position mount with alarm signal siren (H3/1) on longitudinal frame member in right wheelhouse as illustrated and mark mounting hole on longitudinal frame member.
- Drill marked hole with ø 3.5 mm dia. bit.
- Connect 3-pin connector (4) of ATA/AS wiring harness to alarm signal siren and tighten mount to longitudinal frame member with suitable sheet metal screw (3).
Apply corrosion protection agent to holes.