Multifunction control module (CCM) diagnosis fault memory (Fault Code B1000, B1010, B1011, B1013, B1014, B1021, B1024, B1025, B1115, B1217, B1406, B1407) - AD54.21-P-4003A
MODEL 170, 210 / (except 210.081 /281) up to 28.2.97
| Multi-function control module (CCM) diagnosis, previous knowledge | AD54.21-P-2003A | ||
| Fuses in order | |||
| Battery voltage 11 - 14 V | |||
| Ignition ON | |||
| Connect Hand-Held Tester (HHT) and read out fault memory | AD00.00-P-2000-03A | ||
| Fault memory | |||
| Fault code | Possible cause | Note | Remedy |
| B1000 | Multi-function control module (N10-1 or N10-3) | ||
| B1010 | Voltage < 9 V (terminal 30E) | ||
| B1011 | Voltage > 15 V (terminal 30E) | ||
| B1013 | Voltage supply, terminal 15R missing at terminal 15 | AD54.21-P-6003-01B AD54.21-P-6003-01C |
|
| B1014 | Direction of travel indicator terminal 49, no voltage at terminal 15 | AD54.21-P-6003-20A | |
| B1021 | CAN data bus, no communication with PSE, PE | Model 210 | dh0503pa00023x |
| Model 170 | dh0303pa00023x | ||
| B1024 | CAN data bus Low or multi-function control module (N10-1 or N10-3) | Model 210 | dh0503pa00023x |
| Model 170 | dh0303pa00023x | ||
| B1025 | CAN data bus High or multi-function control module (N10-1 or N10-3) | Model 210 | dh0503pa00023x |
| Model 170 | dh0303pa00023x | ||
| B1115 | Rear window defroster switch > 25 seconds, |
AD54.21-P-6003-16A | |
| B1217 | Rain sensor, no communication, check programming in CCM | AD54.21-P-6003-12A Program rain sensor in CCM | |
| B1406 | Actuation of dome lamp by CCM (N10-1 or N10-3), cable |
Model 210 | AD54.21-P-6003-14A |
| Model 170 | AD54.21-P-6003-14C | ||
| B1407 | Exit lamps cable |
Model 210 | AD54.21-P-6003-13A |