Testing pressure at rear axle level controller - AR32.30-P-0530A: Notes
MODEL 140, 210 with CODE (217a) Self-levelling suspension on rear axle with ADS with CODE (480) Level control system at rear
MODEL 202, 203.2, 208 with CODE (480) Level control system at rear
| Removing | |||
| Risk of injury to skin or eyes from hydraulic fluid spraying out under pressure. Risk of poisoning from swallowing hydraulic fluid. | Render the hydraulic system pressureless before commencing work on system. Wear protective clothing and eye protection. | AS00.00-Z-0013-01A | |
| 1 | Drain hydraulic system | AR32.30-P-0630A | |
| General notes for working on vehicles with level control/ADS | All models with Code 216b, 216c, 217a, 480 | AH32.00-P-0002-01A | |
| Inspecting | |||
| 2 | Connect tester to level controller | AR32.30-P-0530-01A | |
| 3 | Fill the reservoir with fluid (2) | ||
| Figure | |||
| Models 140, 202, 208 Fluid conforming to criteria found in Specifications for Service Products |
BB00.40-P-0343-00A | ||
| Model Series 210, 203.2 Fluid conforming to criteria found in Specifications for Service Products |
BB00.40-P-0344-00A | ||
| Risk of accident from vehicle starting off by itself when engine running. Risk of injury from contusions and burns if you insert your hands into the engine when it is started or when it is running | Secure vehicle to prevent it from moving off by itself. Wear closed and close-fitting work clothes. Do not touch hot or rotating parts. |
AS00.00-Z-0005-01A | |
| 4 | Start engine and allow to idle | 4 | |
| 5 | Press suspension-control module lever to position "fill" (F) | ||
| 6 | Check the release pressure of the bypass valve in the hydraulic suspension-control module Note release pressure indicated by gauge. |
||
| Bypass valve release pressure | *BE32.30-P-1001-03A | ||
| 7 | Set level controller lever to "Empty" position (L). | ||
| 8 | Switch off engine | ||
| 9 | Check base pressure of discharge valve in hydraulic suspension-control module Read base pressure on pressure gauge. | The system should reach base pressure after no more than a maximum of 3 minutes. |
*BE32.30-P-1002-03A |
| 10 | Allow the system to settle for approximately 5 minutes, then read the base pressure again. | The base pressure should not drop during this period with the system in its passive state. If pressure falls ↓ | *BE32.30-P-1002-03A |
| Replace the suspension-control module. | AR32.30-P-0670A | ||
| Installing | |||
| Risk of injury to skin or eyes from hydraulic fluid spraying out under pressure. Risk of poisoning from swallowing hydraulic fluid. | Render the hydraulic system pressureless before commencing work on system. Wear protective clothing and eye protection. | AS00.00-Z-0013-01A | |
| 11 | Disconnect tester at level controller | AR32.30-P-0530-01A | |
| 12 | Recharge hydraulic system | AR32.30-P-0630A |
Suspension-control module test specifications
| Number | Designation | Model Series 140 with ride-height control/ ADS | Model Series 202 with ride-height control | Model Series 203.2 with self-leveling suspension | |
|---|---|---|---|---|---|
| BE32.30-P-1001-03A | Bypass valve release pressure | pressure in bar | 120-153 | 120-153 | 120-153 |
| BE32.30-P-1002-03A | Base pressure at discharge valve | pressure in bar | 30-36 | 30-36 | 30-36 |
Suspension-control module test specifications
| Number | Designation | Model Series 208 with self-leveling suspension | Model 210 with level control / ADS | |
|---|---|---|---|---|
| BE32.30-P-1001-03A | Bypass valve release pressure | pressure in bar | 120-153 | 120-140 |
| BE32.30-P-1002-03A | Base pressure at discharge valve | pressure in bar | 30-36 | 30-36 |
| Number | Designation | Model Series 140 with ride-height control/ ADS | Model Series 202 with ride-height control | ||
|---|---|---|---|---|---|
| BA32.30-P-1002-03A | Oil drain plug on level controller (reference value) | M10 x 1 | NM | 14 | 14 |
| Number | Designation | Model Series 203.2 with self-leveling suspension | Model Series 208 with self-leveling suspension | ||
|---|---|---|---|---|---|
| BA32.30-P-1002-03A | Oil drain plug on level controller (reference value) | M10 x 1 | NM | 14 | 14 |
| Number | Designation | Model 210 with level control / ADS | ||
|---|---|---|---|---|
| BA32.30-P-1002-03A | Oil drain plug on level controller (reference value) | M10 x 1 | NM | 14 |