Removing and installing level control valve unit - AR32.31-P-0650I: Notes
MODEL 220 except CODE (487) Active Body Control (ABC)
Fig 1: Identifying Pressure Line Connections (Model 220 Except Code (487) Active Body Control (ABC))
| Remove/install | |||
| Special information on AIRmatic | AH32.22-P-1000-02I | ||
| 1 | Drain AIRmatic system using Star Diagnosis | ||
| 2 | Remove compressor | AR32.22-P-2001I | |
| 3 | Detach plug from AIRmatic pressure sensor (B7) | ||
| 4 | Detach valve unit connector (Y36/6x1) | ||
| 5 | Undo pressure line terminals (1LF, 2RF, 3LR, 4RR, 5CR, P) | If pressure line or its connection fittings are damaged:↓ |
*BA32.22-P-1006-03A |
| Repairing AIRmatic pressure line connection | AR32.22-P-2001-02I | ||
| 6 | Undo nuts (arrows) and remove level control valve unit (Y36/6) | *BA32.22-P-1005-03A | |
| 7 | Remove rubber buffer to level control valve unit | AR32.31-P-0650-01I | |
| 8 | Install in the reverse order | ||
| 9 | Fill AIRmatic system using Star Diagnosis | ||
| 10 | Check AIRmatic for leaks. | AR32.22-P-8100I |
| Number | Designation | Model 220 | |
|---|---|---|---|
| BA32.22-P-1005-03A | Nut of valve unit to bracket | Nm | 8 |
| BA32.22-P-1006-03A | Pressure line of air suspension to valve unit | Nm | 5 |
| BA32.22-P-1007-03A | Rubber buffer to valve unit | Nm | 8 |