Remove contacts from Siemens ELO coupling - AR00.19-P-0120-23A
Secondary release on version with secondary retainer (Siemens ELO)
- Using a suitable tool, grasp the secondary retainer (1) and push it in the direction shown by the arrow into the pre-locking position (first detent) (1a).
Shown on 2-pin Siemens ELO coupling
Fig 6: Secondary Release On Version With Secondary Retainer (Siemens ELO) - Shown On 2-Pin Siemens ELO Coupling
Secondary release on version with retaining clamp (Siemens ELO)
- Using a suitable tool, pry up the side clips of the retaining clamp (1).
- Move retaining bracket (1) upward.
- Detach the retaining bracket (1).
Shown on a 10-pin Siemens ELO coupling
Fig 7: Secondary Release On Version With Retaining Clamp (Siemens ELO) - Shown On A 10-Pin Siemens ELO Coupling
Unpin female contacts from the coupling (Siemens ELO)
- Position the blade holder with clamping pliers
and MQS blade
at the side of the spring shackle for the female connector (2).
- Press the spring tab of the female contact downward and push the female contact (2) out of the chamber of the female contact housing (1). Tug the corresponding cable at the same time to assist the unpinning procedure.
Shown on a 10-pin Siemens ELO coupling