Home >> Mercedes Benz >> 2002 >> C240 Standard >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Accessories Control Systems >> Electrical -- Testing & Repair -- 203 Chassis >> Testing & Repair >> Disconnecting residual engine heat utilization system wiring harness - AR54.18-P-0080-01P

Disconnecting residual engine heat utilization system wiring harness - AR54.18-P-0080-01P

Fig 1: Identifying Front SAM Control Module With Fuse And Relay Module, Connector, Absorber And Gasket
G04733819
  1. Remove gasket (4)
  2. Unplug connector (1).

    NOTES When replacing the REST wiring harness, the branch-off line for socket M15 must be insulated, tied back and routed to the area under the master brake cylinder.

  3. Unplug connector (10).

    NOTES When replacing the REST wiring harness, the branch-off line for the coolant circulation pump must be insulated and tied back.

    Fig 2: Identifying Connector
    G04733820