Charge battery - AR54.10-P-1130P
MODEL 203, 209
| Checking | |||
|---|---|---|---|
| Risk of explosion caused by oxyhydrogen gas. Risk of poisoning and caustic burns caused by swallowing battery acid. Risk of injury caused by burns to skin and eyes from battery acid or when handling damaged leadacid batteries | No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and safety glasses. Only pour battery acid into suitable and appropriately marked containers. | AS54.10-Z-0001-01A | |
| 1 | Check condition of battery | AR54.10-P-1129P | |
| Charging | |||
| 2 | Connect charger to battery | ||
| 3 | Charge battery | 10 A charging current for a 100 Ah battery. Rapid charging: charging current max. |
|
| 50 % of battery capacity for 30 min: e.g. max. 50 A charging current for a 100 Ah battery. |
|||
| Problems with charging battery | Only vehicle with AGM battery. | AF54.10-P-6005A | |
| 4 | Disconnect battery charger | ||
| Checking | |||
| 5 | Test battery after charging, see: ↓ | ||
| Check condition of battery | AR54.10-P-1129P |