Refrigerant pressure sensor, function - GF83.40-P-2126-01I
Function
The refrigerant pressure sensor measures the refrigerant pressure and transfers the value measured to the automatic A/C pushbutton control module via the left signal-acquisition and actuation module and the CAN bus. This value is compared with a stored temperature/ pressure curve. The refrigerant pressure sensor operates within the range of 0 to 35 bar.
Switching off the A/C compressor
The A/C compressor is switched off at the following values.
- Refrigerant pressure < 1.75 bar = A/C compressor off
- Refrigerant pressure > 30 bar = A/C compressor off
Switching on the electric engine/A/C electric fan
The engine/A/C electric fan is switched on at the following values:
- Refrigerant pressure < 12 bar = fan off
- Refrigerant pressure > 20 bar = fan on (100%)
- Refrigerant pressure 12 bar to 20 bar = Infinite linear increase in fan speed (40-100%)