Blower regulator, function - GF83.10-P-2103-01M
Function
With the blower buttons (
) or in the automatic mode a control voltage (0 - 6V) is transferred from the rear A/C pushbutton control module to the rear blower regulator. The latter then regulates the operating voltage for the rear blower (0 - 12 V) depending on the control voltage present. This provides the control of the blower speed in the range of 0 - 100 %.
In the automatic mode the control voltage for the rear blower control is calculated according to the control voltage for the automatic A/C read in by the CAN bus.
| Blower switch position (reading on display) | Blower control voltage (manual) |
|---|---|
| 1 segment | 1.00 V |
| 2 segment | 1.20 V |
| 3 segment | 1.50 V |
| 4 segment | 1.90 V |
| 5 segment | 2.40 V |
| 6 segment | 2.90 V |
| 7 segment | 6.00 V |